These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
1 hour fire rated exterior wall detail.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
Type x gypsum board is wallboard to which non combustible fibers have been added.
To an imaginary line between two buildings on the lot.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Go to work with a building solution that meets building code requirements for fire resistent construction while increasing structural ratings.
Table 1 for one hour rated wall assemblies and table 2 for two hour rated wall assemblies.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Warnock hersey fire resistance rated wall assemblies warnock hersey product listings standards products are certified against astm iso en can cgsb can ulc 1 hour fire resistive rated wall assemblies click the link above each design number below represents a james hardie 1 hour fire resistive wall assembly jh fcs 60 01.
Walls less than 5 feet from the property lot line must be of a listed hour fire1 resistant construction.
American softwood lumber standard ps 20.
It combines flame spread and burn through resistance to give your customers.
To the centerline of a street an alley or public way.
2009 irc requires walls built within 5 of a property line or within 5 of another building on the same property to have a 1 hour fire resistance rating with fire exposure from the exterior of the building note.
Wall framing whichever is closer to one of the following.
Descriptions of successfully tested i joist floor as.
With 1 25 mm type s drywall screws 12 305 mm o c.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
These listings are short summaries to serve as a.
According to the book commercial drafting and detailing a typical one hour fire rated wall consists of 2x4 studs spaced 16 inches from the center of one stud to the center of the next covered by 5 8 inch type x gypsum board.
Lp flameblock is an icc es evaluated component of 1 and 2 hour fire rated wall assemblies and roof deck applications.