This assembly is fire rated for 1 hour from the interior side only except when brick is the exterior facing.
1 hour fire rated wall construction.
To the centerline of a street an alley or public way.
Thickness of insulation item 4 is 3 in and two layers of gypsum board panels 1 2 in.
For occupancies such as stores apartments of fices and other commercial and industrial uses build ing codes commonly require floor ceiling and wall assemblies to be fire resistance rated in accordance with standard fire tests.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Where to install type x drywall.
According to the book commercial drafting and detailing a typical one hour fire rated wall consists of 2x4 studs spaced 16 inches from the center of one stud to the center of the next covered by 5 8 inch type x gypsum board.
When item 7b steel framing members is used nonbearing wall rating is limited to 1 hr.
A typical one hour fire rated wall assembly approved by universal laboratories consists of 2 x 4 inch wood wall studs and r 13 glass fiber insulation faced with a vapor retarding foil filling the cavities.
To an imaginary line between two buildings on the lot.
For this reason a fire rated drywall is sometimes called one hour fire wallboard.
When specified for these 1 hour fire rated assemblies lp flameblock sheathing reduces dead load and wall thickness versus common alternatives.
1 hour fire rated construction non loadbearing acoustical performance reference construction detail description test number stc test number index wt.
If a conventional 1 2 inch thick sheet of drywall will stand up to 30 minutes of fire then the added 1 8 inch found in the type x drywall along with its other properties will double your margin of safety to 60 minutes.
Stud depth is 3 1 2 in min.
To the closest interior lot line.
Thick shall be attached to furring channels as described in item 6.
Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall.
Type x gypsum board is wallboard to which non combustible fibers have been added.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Use special fiberglass rated for use in firewalls.
It also providesbetter substrate for securely fastening exterior facing materials.
7 alternate based on 2 1 2 gauge steel studs and 1 2 face layer laminated ga wp 105153ngc 2318 based on 2 glass fiber.
Mount a 1 1 2 inch fiberglass barrier inside the studs.
The fire resistant rating also requires the rating exposure to be for both sides.