Mount a 1 1 2 inch fiberglass barrier inside the studs.
2 hour fire rated wall construction.
Gyprock has developed a broad range of fire rated systems to help specifiers and builders meet the bca requirements with confidence.
Fire resistance ratings are expressed in the number of minutes or hours a structure can withstand a fire simulation test.
For this reason a fire rated drywall is sometimes called one hour fire wallboard.
All other building classes including.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
50 8 mm light gauge steel h studs that secure two layers of 1 in.
If a conventional 1 2 inch thick sheet of drywall will stand up to 30 minutes of fire then the added 1 8 inch found in the type x drywall along with its other properties will double your margin of safety to 60 minutes.
Fire barrier walls are typically constructed of drywall or gypsum board partitions with wood or metal framed studs.
Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall.
There are many ways to meet the requirements for 2 hour fire rated separation walls including foundation to roof masonry walls separating the units.
19 1 mm air space on each side.
Penetrations penetrations through fire walls such as for pipes and cables must be.
American softwood lumber standard ps 20.
An increasingly common and popular method is the gypsum area separation wall which consists of individual stud framed walls filled with fiberglass insulation for each housing unit which are separated by a special construction that consists of.
Building and structural firewalls in north america are usually made of concrete concrete blocks or reinforced concrete older fire walls built prior to world war ii used brick materials.
Table 1 for one hour rated wall assemblies and table 2 for two hour rated wall assemblies.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins.
Descriptions of successfully tested i joist floor as.
Use special fiberglass rated for use in firewalls.
The bca includes requirements for fire performance of walls and ceilings to help ensure occupant safety in the event of a fire.
As applied to elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated.
Class 2 to 9 buildings.
Lumber shall be identified by the grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with the.