Fire alarm cable shielded 300v 18 awg 2 conductor solid bare copper pvc aia csa ft4.
2 hour rated fire alarm mc cable.
Fhit 40a and fhit7 40a for use as cic cable installation follows fhit 40a fhit7 40a and comtran s installation instructions.
The ul fhit number system for each manufacturer s product type describes the tested installation of cable components and assembly which leads to its certification as a two hour fire rated system.
Refer to r27557 fire resistive cable ul vitalink brand type fplr ci st1 cmr ci ls cl3r ci st1 for use in system no.
Red alert type mc fplp fire alarm and control cable view pdf.
Refer to installation instructions for hardware certifications.
120 of the ul fire resistance directory.
Vitalink 2 hour fire rated ci cable applications.
Copper weatherproof line wire.
Ul listed nec type mc in accordance with ul standard 1569 2 hour fire rated per ul standard 2196 following astm e119 1 850 f with water hose stream electrical circuit integrity systems fhit system no.
Emergency voice alarm communication smoke and fire alarm systems fireman s telephone and area of refuge communication systems visible notification appliances compliances.
For use as ci cable installation follows the nec and local code.
Download spec sheet pdf 132 19kb add to quote.
The facu or fire alarm control unit is not required to be 2 hour rated nor are the field devices such as fire fighter s telephone jacks speakers strobes horns etc.
2 type fplr fplr power limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor all fplr cables are listed as having fire resistant characteristics capable of preventing fire from traveling from floor to floor riser cables must pass both ul test 1424 and the vertical riser.
Ed walton a consultant to the wire and cable industry said.
Cable tray rated install per nec federal specification a a 59544 formerly j c 30b ul classified 1 2 and 3 hour through fire penetration product r14141 nfpa 262 formerly ul 910 plenum rated type fplp made in usa of us and or imported materials fire alarm control cable type mc dual rated type mc fplp.
Fa 5c 16 round shld csa.
So how is it that we have codes in place to insure that our fire alarm circuit pathways are secure for a period of 2 hours but not the control or notification equipment.
The cable s electrical listing is not affected by this qualification and.
Comtran vitalink 2 hour fire rated cable 18 2 fire alarm cable fplr riser unshielded color.
Fplp fire alarm cable view pdf.
Download spec sheet pdf 105 11kb add to quote.
Fplr fire alarm cable view pdf.
Comtran s line of vitalink cable featuring fplr circuit integrity cable is designed for use in a wide range of critical systems including emergency voice alarm communication evac smoke fire alarm systems fireman s telephone and area of refuge communication systems and visible.
Fas lvt fire alarm cable view pdf.